Shell & Tube Type Heat Exchanger Specification
- Max Pressure
- 25 bar
- Diameter
- 500 mm (Shell Diameter)
- Thickness
- 6 mm (Shell), 2 mm (Tube)
- Air Volume
- Not Applicable (For Liquid-to-Liquid Exchange)
- Temperature
- Up to 160C
- Max. Capacity
- 15000 LPH
- Number of Pipe
- Approx. 72 tubes (customizable)
- Condition
- New
- Structure
- Shell & Tube Type
- Liquid Flow Rate
- 5000 to 15000 LPH (litres per hour)
- Working Presssure
- 10-25 bar (customizable)
- Power
- Not Applicable (Passive Heat Exchange Device)
- Weight
- Approx. 200 kg
- Dimensions
- 1800 mm (Length) x 500 mm (Diameter) (Standard Size)
Shell & Tube Type Heat Exchanger Trade Information
- Minimum Order Quantity
- 1 Piece
- Payment Terms
- Cash in Advance (CID), Cheque, Cash Advance (CA)
- Delivery Time
- 2 Week
- Packaging Details
- Wooden Box Packaging.
- Certifications
- MSME Certifications.
About Shell & Tube Type Heat Exchanger
We have reached the pinnacle of success and earned a reputed name by providing high quality range of Shell and Tube Chiller. This chiller is manufactured using superior quality components and highly advanced techniques. The provided chiller is highly efficient and requires minimum floor space and head space. Due to its high durability and low maintenance, the provided chiller is widely used in medium to large capacity refrigeration systems. Beside, our clients can purchase this Shell and Tube Chiller from us at marginal rates.
Key Points:
- Excellent performance
- Cost effective
- Trouble free operation
- Excellent design and finish
Superior Material Selection
Choose between Stainless Steel 304/316 and Mild Steel for your heat exchanger, tailored to process needs and corrosion resistance. These materials ensure longevity in harsh environments such as chemical, pharmaceutical, or refinery plant operations. Our careful material selection helps reduce maintenance frequency and operational downtime, allowing for uninterrupted productivity.
Customizable Design for Versatility
With features like horizontal or vertical orientation, optional insulation, and customizable tube numbers and lengths, our shell and tube heat exchanger adapts to varied plant layouts. The flanged end connection allows easy integration into existing pipelines while a heat transfer area of 12 m and support for up to 15,000 LPH fluid flows provide operational flexibility across industries.
Robust Engineering, Tested for Safety
Every unit is pressure-tested up to 30 bar to ensure structural integrity and operational safety. Thick shell (6 mm) and tube (2 mm) walls enhance reliability under demanding conditions. The passive heat exchange design, with no power input, offers high energy efficiency with minimal maintenance, making it ideal for critical and continuous processing applications.
FAQs of Shell & Tube Type Heat Exchanger:
Q: How is the material of construction selected for the Shell & Tube Heat Exchanger?
A: The choice between Stainless Steel 304/316 and Mild Steel is determined by process requirements, particularly relating to operating pressures, temperatures, and potential corrosive exposure. Stainless steel is preferred for its high corrosion resistance in chemical and pharmaceutical plants, while mild steel is used where budget and specific process compatibility allow.Q: What industries commonly use this Shell & Tube Type Heat Exchanger?
A: This heat exchanger is widely used in chemical processing, pharmaceuticals, refineries, food processing industries, and power plants. Its robust construction and customizable features make it ideal for demanding thermal applications across these sectors.Q: When should the optional insulation be considered for installation?
A: Optional insulation is recommended when heat loss to the environment needs to be minimized or when working with high-temperature fluids (up to 160C). Insulation helps improve energy efficiency and maintain desired fluid temperatures during heat exchange.Q: Where can the heat exchanger be installed?
A: The unit can be floor-mounted in a horizontal orientation (standard) or mounted vertically if required by the facility layout. Its compact size (1800 mm length, 500 mm diameter) and customizable connections ensure flexibility in installation locations within the plant.Q: What is the process for maintaining the Shell & Tube Heat Exchanger?
A: Routine maintenance involves periodic cleaning of the tubes to remove scaling or fouling, inspection for leaks at flanged connections, and, if applicable, checking the integrity of insulation. The high corrosion resistance of the materials reduces the frequency of major repairs.Q: What are the key benefits of using this heat exchanger design?
A: The shell and tube design offers efficient heat transfer, adaptability to various flow rates up to 15,000 LPH, high pressure/temperature resilience (up to 25 bar and 160C), easy customization, and low energy consumption due to its passive operation, ensuring process reliability and lower operational costs.
Tell us about your requirement
Price:
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+
Additional detail
Mobile number
Email
More Products in Heat Exchanger Category
![]() |
S.M. CHILLERS INDIA PRIVATE LIMITED
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |